@article{Y.Evangelin_J.Ijeya_K.Sruthi_M.Sagar Babu_N.Hemanth Reddy_S.Divya Sai Bhaskar_2023, title={A stability indicating rp-hplc method developement for the simultaneous determination of ketorolac and olopatadine in bulk and in its pharmaceutical dosage forms}, volume={11}, url={https://ijamscr.com/ijamscr/article/view/1316}, DOI={10.61096/ijamscr.v11.iss2.2023.129-135}, abstractNote={A simple, rapid and precise reverse phase liquid chromatographic (RP-HPLC) method was developed and validated for the estimation of Ketorolac and Olopatadine. In this method an Symmetry C18, 250×4.6mm, (innertsil ODS). 5µ or equivalent in an isocratic mode utilizing Phosphate Buffer (4.6 pH): Acetonitrile (50:50%v/v) at a flow rate of 1.0 ml/ min and effluent was monitored at 219 nm. Olopatadine hydrochloride& Ketorolac tromethamine was 2.724, 3.849 minutes. The linearity range was found to be 25 to 150µl. The validated method was very linear and precise.}, number={2}, journal={International Journal of Allied Medical Sciences and Clinical Research}, author={Y.Evangelin and J.Ijeya and K.Sruthi and M.Sagar Babu and N.Hemanth Reddy and S.Divya Sai Bhaskar}, year={2023}, month={Apr.}, pages={129–135} }